Configuring SDSL Cell Alarm Profiles

402

Avidia System Configuration and Management User Manual

The

SDSL Cell Alarm Profile Table

window displays the configured SDSL cell alarm profiles.

Click

and

if necessary to view the entire table.

displays the beginning of the table.

displays the next page of the table.

Adding SDSL Cell Alarm Profiles

You add SDSL cell alarm profiles from the

SDSL Cell Alarm Profile Table

window.

1

In the

Loss of Cell Delineation

box, type a value for this threshold, or type

0

to disable the

trap.

The loss of cell delineation threshold determines the acceptable number of seconds in a
15-minute SDSL cell performance data collection period during which some cells
transmitted during that second were lost.

2

In the

Severe Loss of Cell Delineation

box, type a value for this threshold, or type

0

to disable

this trap.

The severe loss of cell delineation threshold determines the acceptable number of seconds
in a 15-minute SDSL cell performance data collection period during which the total number
of LOCD events in that second exceed 50% of the total bandwidth available during that
second.