Cpc400 attributes – Watlow LogicPro User Manual
Page 51

LogicPro User’s Guide
Chapter 4: Resources
Doc.# 28002-00 Rev 3.00
Watlow Anafaze
35
To configure communications with the PPC-2000:
1.
Select the correct
Communication Port
for your PC.
2.
Select a
Parity
of
Even, Odd
or
None
.
3.
In the
Device Address
field, enter the controller
address for the PPC-2000.
4.
In the
ROM Size
field, enter 128kB. (Controllers with
2.03 and earlier firmware support up to 40 kB.
5.
Select a
Baud Rate
. The PPC-2000 supports
9600
and
19200
.
6.
In the
Time out
field, enter 2000 milliseconds.
7.
Click
[OK]
-or-
Click
[Cancel]
to exit this screen.
CPC400 Attributes
The CPC400 has the following default communication
settings:
•
Baud Rate: 19200
•
Controller Address: 1
To configure communications with the CPC400:
1.
Select the correct
Communication Port
for your PC.
2.
Select a
Parity
of
None
.
3.
In the
Device Address
field enter the controller
address you set in the CPC400.
4.
In the
ROM Size
field, enter 64 kB.
5.
Select a
Baud Rate
. The CPC400 supports
2400
,
9600
and
19200
.
6.
In the
Time out
field enter 2000 milliseconds.
7.
Click
[OK]
-or-
Click
[Cancel]
to exit this screen.