Analog_Out_205x

The Analog_Out_205x driver supports the outputs on the PPC-205x
series Analog Output modules.

To associate a variable with an analog output:

1.

Open the Add Program/Resource Variable dialog box.

2.

Enter a unique variable Name.

3.

Select INT from the Type list.

4.

Select Output by clicking the check box.

5.

Select Analog_Out_205x from the IO Driver list.

6.

Select WORD from the IO Size list.

7.

Enter the IO Physical Address. The address is:
X.Z

X is the module address (31-34)
Z is the module I/O number (1-8)

8.

Click

[OK]

.

PPC-205x Analog Out Addressing Example

To create a variable named VoltsOut_2 that sets the level of the
second output on a PPC-205x module with its rotary address switch
set to 31, set the options in the Add Program/Resource Variable
dialog box as illustrated below.