beautypg.com

Fairbanks X SERIES PR 5410 Process Indicator User Manual

Page 98

background image

Section 4: Commissioning

10/08 98

51207 Revision 1

The output signal (Limit 1
out) of limit 1 switches OFF
above a weight of 900 kg.
The output signal (Limit 2
out) of limit 2 switches OFF
below a weight of 290 kg.
Both limit values have a
hysteresis of 10 kg.

In the event of a power
failure, the two outputs go to
OFF, thus indicating underfill
and overfill at the same time.

If the limits (Limit 1 and Limit
2) for 'On' and 'Off' are equal
(on = off), output 1 (Limit 1
out) switches ON, when the
weight (Wgt) exceeds the
value and output 2 (Limit 2
out) switches OFF, when the
weight drops below the value.

Setup/Limit parameter

Limit 1 on

900 kg

Action

set marker 1

X64=1

Condition

no condition

-----