Fairbanks X SERIES PR 5410 Process Indicator User Manual
Page 5
Table of Contents
10/08 5
51207 Revision 1
3.5 C
ONNECTING
L
OAD
C
ELLS
,
C
ONTINUED
3.5.3
Connecting up to 8 Load Cells (650 Ohms) Using 6-Wire Connecting Cable
53
3.5.4
Connecting Load Cells with External Supply
54
3.5.5
Connecting Load Cells via Intrinsically Safe Load Cell Interface PR 1626/60
55
3.5.6
Connecting Platforms (CAP...)
56
4
Commissioning ........................................................................................................... 57
4.1 D
ATA
P
ROTECTION
/P
OWER
F
AILURE
........................................................................................ 57
4.1.1
CAL Switch
57
4.2 S
WITCHING ON THE
I
NSTRUMENT
.............................................................................................. 58
4.2.1
Display Test
58
4.2.2
Front-Panel Key Test
58
4.2.3
Resetting the Instrument to the Factory Settings
58
4.2.4
Setting the Network Address Using Front-Panel Keys
59
4.2.5
Viewing the Network Address via Front-Panel Keys
59
4.2.6
Searching the Instrument in the Network Using 'IndicatorBrowser'
59
4.2.7
Loading New Software
60
4.3 C
ONFIGURATION AND
C
ALIBRATION USING
F
RONT
K
EYS
........................................................... 61
4.3.1
Meaning of Front Keys
61
4.3.2
Entering Date and Time
61
4.3.3
Parameter Table
62
4.3.4
New Calibration using Front Keys
64
4.3.5
Subsequent Change of Deadload using Front Keys
65
4.3.6
View Calibration Data
65
4.3.7
View Calibration Data for Deadload and Maximum Load
66
4.3.8
PIN Code
66
4.4 O
PERATION
U
SING A
PC .......................................................................................................... 67
4.4.1
Operation Using the VNC Program
67
4.4.2
Operation Using Internet Browser
68
4.4.3
INFO Function
69
4.4.4
Setup Function (VNC)
70
4.4.5
Setup Menu (VNC): Overview
70
4.4.6
Calibration Menu
71
4.5 C
ALIBRATION
........................................................................................................................... 72
4.5.1
Displaying Calibration Data
72
4.5.2
Selecting the Calibration Mode
73
4.5.3
Determining the Maximum Capacity (Max)
74
4.5.4
Determining the Scale Interval
75
4.5.5
Determining the Dead Load
75
4.5.6
Calibration with Weight (by Load)
76
4.5.7
Calibration with mV/V Value
77
4.5.8
Calibration with Load Cell Data (“Smart Calibration“)
78
4.5.9
Subsequent Dead Load Correction
79
4.5.10
Linearization
80
4.5.11
Test Value Determination / Display
80
4.5.12
Finishing / Saving the Calibration
81
4.5.13
Parameter Input
81
4.6 E
RROR
M
ESSAGES
................................................................................................................... 85
4.6.1
Measuring Circuit Error Messages
85
4.6.2
General Error Messages
85
4.7 C
ONFIGURING
G
ENERAL
P
ARAMETERS
..................................................................................... 86
4.7.1
Date and Time
86
4.7.2
Serial Ports
86
4.7.3
SMA Protocol
88
4.7.4
EW Protocol
88
4.7.5
Operating Parameters
89
4.7.6
Printing Parameters
90