Section 7: Fieldbus Interface

10/08 128

51207 Revision 1

7

Fieldbus Interface

7.1 F

IELDBUS

I

NTERFACE

P

ROTOCOL


The interface works with an 8-byte write window and an 8-byte read window. The fieldbus
exchanges its data cyclically with each slave. This means: In each cycle, 8 bytes are written and 8
bytes are read, also if the data content is unchanged.
The fieldbus protocol ensures the data transport between the fieldbus master and the 2 x 8-byte
data windows.
The interface protocol runs under the fieldbus and manages the access to a multitude of different
data.

Fieldbus Interface

Data and Functions with PR 5410

-

Weight data

-

Weight status

-

Limit values

-

Digital inputs

-

Digital outputs

-

Analog output

8-Byte

Write Window

8-Byte

Read Window

Interface

Protocol