Fairbanks X SERIES PR 5410 Process Indicator User Manual
Page 55
Section 3: Installing the Instrument and Plug-In Cards
10/08 55
51207 Revision 1
3.5.5 Connecting Load Cells via Intrinsically Safe Load Cell Interface PR 1626/60
The cable colors shown here are
valid for the PR 62.. series load cells
and for PR 6135 and PR 6136
connecting cables.
When using other load cells, the
assignments of cable colors may differ.
For this reason, the relevant manual or
data sheet should be consulted for
assignments of cable colors before
connecting.
When using the PR 1626/60 intrinsically
safe load cell interface with 7.5 VDC
(MX 8 closed), open the solder link on
the main board of PR5410 to switch the
sense voltage detection.
The PR5410 load cell supply must not
be connected.