Section 3: Installing the Instrument and Plug-In Cards

10/08 47

51207 Revision 1

3.4.10 PR 1721/32 Interbus Interface

The Interbus interface PR 1721/32 is a plug-in card for installation in Slot 4; see Chapter 3.4.1.
The interface is based on the Interbus chip technology and enables transfer rates of 500 kbit/s and
2 Mbit/s.

Internal
connection:

34-pin connector on flat cable, only
for Slot 4

External
connection:

Standard IBS 9-contact D-Sub
socket OUT and D-Sub plug IN in
retainer plate

Bus In Bus Out

Transfer rate:

500 kbit/s or 2 Mbit/s, selectable

Topology:

Bus as a closed ring

Protocol:

INTERBUS-S master-slave
fixed telegram length, deterministic
cyclical process data transmission
with max. 10 words I/O.

Transport:

EIA RS-422, cable-bound

Cable:

Interbus, color: green
3x2 twisted pairs, common shield

Cable impedance: 150 ohms
Lead termination:

Not required, due to active ring
topology

Certificates:

From Interbus Club e.V.:
Compatibility with Interbus standard
IEC 61158 (Parts 3 to 6)
EN 50254 (DIN 19258)
Suitable for industrial applications
CE, UL & cUL

Dimensions
(LxWxH):

87 x 55 x 15 mm

Electrical isolation: Yes, optocoupler and DC/DC

converter

Weight:

125 g

Cable length:

400m (between two remote bus
sharing units). Overall length: 13 km

With Bus OUT , 5 and 9 must be bridged if another slave follows.