Section 4: Commissioning
10/08 85
51207 Revision 1
4.6 E
RROR
M
ESSAGES
4.6.1 Measuring Circuit Error Messages
The weighing electronics can generate error messages, which are output on the weight display.
Display
VNC text
Cause
EPPOP1
Arith err
Internal arithmetic overflow (faulty calibration values)
EPPOP2 Overload
Input voltage is higher than Max + (x d)
EPPOP3 No EOC
Input signal is higher than the permissible range of 36 mV.
However, the trouble cause can also be due to an error in the
analog section, to a defective load cell or to a cable break
EPPOP6 No sense
voltage
Load cells not connected. Sense line or supply line is interrupted or
connected with wrong polarity or sense voltage is low
EPPOP7 Negative Input
Input voltage is negative (e.g. wrong polarity of load cell signal or
supply voltage)
Testing the Measuring Circuit
A simple test with the load cells connected can be carried out with a multimeter
(not with external supply or intrinsically safe load cell interface):
12 VDC +/- 0.8 V
(symmetrical to housing GND)
12 VDC +/- 0.8 V
(symmetrical to housing GND)
0 - 12 mVDC @ LC with 1.0
mV/V
0 - 24 mVDC @ LC with 2.0
mV/V
Supply voltage
Sense voltage
Measuring voltage
4.6.2 General Error Messages
Display
Cause
EPP 21
The BIOS is too old for the firmware
EPP 22
The firmware is too old for the BIOS
EPP 23
Starting is not possible; ROM error
EPP 25
The plug-in card combination is not permissible
EPP 29
Flashing failed
EPP 31
The IP address is faulty, e.g. item > 255
EPP 32
The IP address is already used
EPP 33
Wrong parameter
EPP 41
Fatal system error
EPP 42
Fatal control system error