beautypg.com

Fairbanks X SERIES PR 5410 Process Indicator User Manual

Page 24

background image

Section 3: Installing the Instrument and Plug-In Cards

10/08 24

51207 Revision 1

3.4 A

CCESSORIES

3.4.1 Installing Plug-in Cards

The main board has two slots with identical pin allocation (34 contact pins in two rows of 17) and
another slot (34 contact pins in two rows of 17) for plug-in cards. The slot designations are “Slot 1 ...
2" and "Slot 4" (left). Up to 2 cards can be mounted. Accordingly, the back panel is provided with
two cut-outs for the retainer plates of the cards.

Before installing or removing a plug-in card, disconnect the instrument from all voltage
sources.

View from above, back panel connectors at the

bottom

Installation (Slots 1-2, 4):
The flat cables plug into connectors (Slots 1
... 2, 4) on the main board. The cables are
polarized; i.e. incorrect polarity is precluded.

A description and examples of the various
cards and connections are given in Chapter
3.3.3 .


Remove the dummies from the back panel (2
screws; M3) and replace them with the
retainer plates for the plug-in cards.

The flat-cable connectors must be inserted
into the corresponding slots on the main
board.

View from the back

After installation/modification, the plug-in cards are detected automatically.

To view a list of the installed plug-in cards, select

-[Show HW-slots]:

Info/HW-Slots

Builtin

RS 232 Built-in serial interface

Slot 1

PR
5510/04

RS 485/232 Slots (Slot 1 and 2) are identical

Slot 2

-empty-

Slot 3

Builtin

Digital I/O Built-in digital I/Os

Slot 4

PR
1721/31

Profibus-DP

Only Fieldbus cards