Section 2: Process Indicator

10/08 12

51207 Revision 1

2

Process Indicator

The instrument is equipped with a six-digit 7-segment display and additional status indication. Local
operation is performed using 6 double-function keys.

2.1 O

VERVIEW OF THE

I

NSTRUMENT

-

Accuracy 10,000 e (Class III) for the weighing electronics

-

High-speed conversion with response times from 10 Msec

-

Weight indication with status by transflective 6-digit 7-segment display

-

6 function keys for front-panel operation

-

Front panel rated to IP 65, back panel to IP30

-

LAN adapter with 10/100 Mbit/sec (built-in)

-

RS-232 interface, built-in; for connecting e.g. a printer or a remote indicator

-

Expansion possible by addition of plug-in circuit boards (2 slots)

-

Galvanically isolated interfaces (except RS-232, analog input and BCD output)

-

Wide range power supply for 100 to 240 V AC, protection class I (protective earth)

-

Version PR 5410/01 for 24 VDC direct current

-

Plug-in connections on the back panel for load cells, inputs/outputs, LAN adaptor

-

Suitable for mounting in a panel cut-out or a control cabinet

-

Calibration using front keys or PC tool (Browser/VNC)

-

Calibration using weights, by entering mV/V values,
or directly, using load cell data ("smart calibration")

-

Software configuration of the interface cards, e.g. for remote display or printer

-

Analog test for the weighing electronics



Communication protocols:

For the internal RS-232 or RS-232/-485 (see Accessories):

-

Remote display

-

Printer, standard or legal for trade

-

JBUS/MODBUS (slave)

-

SMA

-

Asycom


Fieldbus slave with PR 1721/3x (see Accessories):

-

Profibus-DP

-

Interbus-S

-

DeviceNet

-

EtherNet/IP


or PR 5510/14 Ethernet for Modbus TCP/IP