Section 3: Installing the Instrument and Plug-In Cards

10/08 29

51207 Revision 1

Connecting a PR 1627 Remote Display over RS-485

Four-wire transmission, point to point, full duplex (simultaneous sending and receiving possible)
with PR 1627/00 remote display.

Configuration:

-[Serial ports parameter]-[Remote display]-[Slot1/2-RS-485]



RS-422 Point-to-Point Connection (Four-Wire)

Four-wire transmission: full duplex (simultaneous sending and receiving possible)
RS-422 can be used only for point-to-point connection.

Configuration:

-[Serial ports parameter]-[.........]-[Slot1/2-RS-485]