Fairbanks X SERIES PR 5410 Process Indicator User Manual
Page 91
Section 4: Commissioning
10/08 91
51207 Revision 1
4.7.7 Fieldbus Parameters
Setup
Serial ports parameter
Date & Time
Operating parameter
Printing parameter
Fieldbus parameter
Select [Fieldbus parameter] with
and
This menu item can only be selected if a Fieldbus card is installed in Slot 4.
Fieldbus Protocols
Which protocol is displayed automatically depends on the Fieldbus card installed:
[Interbus-S] for PR 1721/32, [Profibus-DP] for PR 1721/31, [DeviceNet] for PR 1721/34,
[EtherNet/IP] for PR 1721/37 and [ModBus TCP] for PR 5510/14.
Setup/Fieldbus
Fieldbus protocol
Profibus-DP
Which additional parameters are required, depends on the interface type:
[Interbus-S]
Setup/Fieldbus
Fieldbus protocol
Interbus-S
[Profibus-DP]
Setup/Fieldbusparameter
Fieldbus protocol
Profibus-DP
Profibus-DP Address
1 Enter address
[DeviceNet]
Setup/Fieldbus
Fieldbus protocol
DeviceNet
DeviceNet baudrate
500k Press
to select 500, 250 or 125 k
DeviceNet MAC-ID
1 Select address 1 ... 62
[ModBus TCP] or [EtherNet/IP]
Setup/Fieldbus
Fieldbus protocol
ModBus TCP 100 MB/s
IP address
192.168.1.1 Enter IP-address
Subnet mask
255.255.255.0 Enter Subnet mask
Closing the menu
Save changes?
To close the menu, press
. Reply [YES] to save the data, or [NO] to
close the menu without changing data.