Global spm variables, continued – Fairbanks X SERIES PR 5410 Process Indicator User Manual
Page 140
Section 8: Global SPM Variables
10/08 140
51207 Revision 1
Global SPM Variables, Continued
BYTE
R
Indicator status
B4
BYTE
R
ADC status
B5
BYTE
R
Command status
B6
BYTE
R
Exponent (digits behind the decimal point)
B16
BYTE
R
Weight unit 2:g, 3:kg, 4:t, 5:lb
B17
BYTE
R
Scale interval (multi-interval / multiple range: d1 or e1)
B18
USINT R
Last error
B19
DINT
R
Current gross weight
D8
DINT
R
Current net weight
D9
DINT
R
Current tare weight
D10
DINT
R
Current gross / net weight selected with X72
D11
DINT
R
Max weight (full scale deflection)
D14
DINT
W
Weight limit 1 on
D24
DINT
W
Weight limit 1 off
D25
DINT
W
Weight limit 2 on
D26
DINT
W
Weight limit 2 off
D27
DINT
W
Weight limit 3 on
D28
DINT
W
Weight limit 3 off
D29
UDINT W
Analog output for 'transparent' mode
D30
DINT
W
Write the value in the fixtare memory
D31
DWOR
D
W
BCD value for 'transparent' mode
D20
UDINT R
Serial number
D6