Section 3: Installing the Instrument and Plug-In Cards

10/08 49

51207 Revision 1

3.4.12 PR 1721/37 EtherNet/IP Schnittstelle

The EtherNet/IP interface is a plug-in card for installation in Slot 4, see chapter 3.4.1. The card is
fitted with a standard RJ-45 socket for Ethernet connection and contains a powerful TCP/IP and
EtherNet/IP connecting circuitry with transfer rates of 10 and 100Mbits/s.

Internal connection:

34-pin connector on flat cable for

Slot-4

External connection:

RJ-45 connecting socket in holding

plate

Transfer rate:

10Mbit/sec and 100Mbit/sec
Autodetection (10/100,
HalfDX/FullDX)

Connection mode:

Network

Protocol:

EtherNet/IP

Transport:

TCP/IP oder UDP/IP

Cable:

Twisted pairs, screened
e.g. patch cable CAT5
Autolink (straight oder crossover)

Cable impedance:

150 Ohm

Cable length to HUB: Max. 115 m
Certificates:

EtherNet/IP Specification
ODVA File No. 10286
Test Date: 06.09.2005
Vendor ID 90
See also: www.odva.org
Tested according to: CE, UL & cUL

Potential isolation:

Yes

Dimensions (LxWxH): 87 x 55 x 15mm

Weight:

125 g

The EtherNet/IP card is supported from PR 5410 Firmware Release 1.30 onwards. The IP-Address
and the Subnet-Mask are set at Fieldbus parameter FP 96 und 97 (see chapter 4.7.7 and Error!
Reference source not found.
).

Take care, that switches 1 - 8 are set to (OFF)

LED 1

LED 2

LED 3

LED 4

Off

No connection (HW) No power

No power o.
No IP Address

On green

Connection (HW)

Controlled by a
scanner

Online,
connection
established

On red

Major unrecoverable
fault

IP Address double,
fatal error

Flasching green

Not configured o.
scanner in idle state

Online, no connection
established

packet is received or
transmitted

Flashing red

Minor recoverable
fault

Connection timeout

Alternat.
red/green

Self test in progress Self test in progress

Watchdog LED

Flashing 1Hz
green

Modul initialized and running without problems