Section 4: Commissioning

10/08 59

51207 Revision 1

4.2.4 Setting the Network Address Using Front-Panel Keys

Press Setup at the instrument

DS,PTS,Tw

Press

to reach the BIOS menu

BIOS w

Press

BIO,S..w

Is displayed, followed by

FLASH w

Press

to reach the menu

NET w

Press

I,PADDRw

Instrument will display the IP-address next

 00,000,0

The most significant part of the address* is displayed, with the position is selected
(the current digit blinks) and press

/

to select the digit

 00,000,0

By the least significant part of the address* can be set, continue with

MASK w

Instrument will display the mask next

22525,0w

The most significant part of the mask* is displayed, with the position is selected (the
current digit blinks) and press

/

to select the digit

24,000,0w

By the least significant part of the address* can be set, continue with

SAVE 0w

It is asked, whether address and mask should be stored

SAVE 1w

Alter with

the '0' to '1' for storing and confirm with

DONEw

Is displayed to indicate the execution

ERR31w

* Error message, if digit group for IP-address / mask is not within 0 - 255

For DHCP (Assignment by server) the address has to be set to

 00,000,0w

 00,000,0w

.


4.2.5 Viewing the Network Address via Front-Panel Keys

Press Setup at the instrument

DS,PTS,Tw

Press

to reach the BIOS menu

BIOS w

Press

BIO,S..w

Is displayed, followed by

FLASH w

Press

ETHERw

Press

DHC,P..w

Instrument is waiting for address assignment by the server

17,202,4w

The most significant part of the Ethernet address is displayed

2,108,1w

Subsequently the least significant part of the Ethernet address is displayed

FLASH?w

Terminate with

Caution: In case of restart, a new address may be assigned by the server.


4.2.6 Searching the Instrument in the Network Using 'IndicatorBrowser'


The address can be determined using the 'IndicatorBrowser' program (stored in a directory on the
enclosed CD-ROM).

When connecting the instrument to a network, it is
“default“ in the DHCP mode; i.e., an address is
assigned to it by the server. This address, e.g.,
172.24.21.85, can be determined using the
'IndicatorBrowser' program.