3.4.9 PR 1721/31 Profibus Interface

Profibus interface PR 1721/31 is a plug-in card for mounting in Slot 4; see Chapter 3.4.1.
Communication protocols and syntax comply with the Profibus-DP standard to IEC 61158, with
transfer rates up to 12 Mbit/s.

Internal
connection:

34-pin connector on flat cable for Slot
4

External
connection:

9-contact D-Sub socket in retainer
plate

Transfer rate:

9.6 kbit/s to 12 Mbit/s,
baud rate auto-detection

Connection mode: Profibus network,

connections can be made/released
without affecting other stations

Protocol:

PROFIBUS-DP-V0 slave
to EN 50 170 (DIN 19245),
mono or multi-master systems
are supported. Master and slave
devices, max. 126 nodes possible.
Watchdog timer

Transport:

EIA RS-485 , Profibus DIN 19245
Part 1

Cable:

Special Profibus color: violet
Shielded twisted pair cable

Cable impedance: 150 ohms
Bus termination

Can be activated externally via DIL-
switch

Certificates:

Profibus test center Comdec in
Germany and PNO (Profibus User
Organization). Suitable for industrial
applications to CE, UL and cUL

Dimensions
(LxWxH):

87 x 55 x 15 mm

Electrical isolation: Optocoupler in lines A and B (RS-

485)

Weight:

125 g

Cable length:

Max. distances 200m can be
extended with 1.5 Mbit/s by means of
additional repeater.

Make sure the two rotary switches are set to position 0.
The terminating resistors can be switched on and off by pressing switch .