beautypg.com

Fairbanks X SERIES PR 5410 Process Indicator User Manual

Page 88

background image

Section 4: Commissioning

10/08 88

51207 Revision 1

4.7.3 SMA Protocol

Select an RS-485 interface under

-[Serial ports parameter].

Setup/Serial ports

Printer

- none -

Remote display

Slot1 RS232

JBUS/MOD-Bus

Slot2 RS485

SMA

Slot1 RS485

Param


Only the baud rate is adjustable; the other parameters are fixed.

Setup/Serial ports/Slot1 RS485

Assigned to

SMA

Protocol

SMA

Baudrate

9600 bd Press

to select [Baudrate] and

Bits

8

set the baud rate with

Parity

none

Stopbits

1

The SMA protocol is described in Chapter 4.8.

4.7.4 EW Protocol

At configuration of serial ports

-[Serial ports parameter] a serial port for [Asycom] has to be

selected and the protocol and communication parameters have to be set.

Setup/Serial ports

Printer

- none -

Remote display

Slot1 RS232

JBUS/MOD-Bus

none

SMA

none

Asycom

Slot1 RS485

Param

Setup/Serial ports/Slot1 RS485

Assigned to

Asycom

Protocol

Asycom V1 Select V1, V2 or V3

Baudrate

9600 bd Select e.g. [Baudrate] with

and with

Bits

8

the transfer parameter

Parity

even

Fixed setting

Stopbits

1

Fixed setting

Slave

A Select A - Z

The PR 1612 Instructions for the EW-Protocol are described in chapter 6 .