Chapter 10

Tuning, Troubleshooting, Security, and Maintenance

ITO Security

Or locally on each of the managed nodes:

/opt/OV/bin/OpC/install/opc_sec_register.sh

These steps can be repeated if necessary.

NOTE

To undo any of the steps you have carried out using the script

opc_sec_register_svr.sh

or

opc_sec_register.sh

, use the

-remove

option.

5. Use the ITO GUI to select the appropriate security level for the

managed node or management server using DCE RPCs. By default,
the security level is set to “No Security”. To set or change the security
level:

a. Open the

ITO Node Bank

window.

b. Click the node whose security level you want to change.

c. Open the following sequence of windows:

Actions:Node->Set Defaults->Advanced Options

if you want to change the default setting for all nodes, or:

Actions:Node->Modify->Advanced Options

if you want to change the default setting for an individual node

d. Fill in the relevant fields in the

Communications Parameters

section. ITO’s online help provides guidance on the options
provided.

e. Close the

Advanced Options

window.

f. Click

[OK]

in

the ITO Node Defaults

or

Node Modify

window.

NOTE

Note that the domestic version of DCE (dced.Dom U.S./Canada only)
must be installed. If you select a DCE Security Level in the

Node

Advanced Options

window, but have no domestic version installed, the

communication between the ITO agent and the management server will
fail. If this happens, set the DCE Security Level to

No Authentication

of RPCs

, and remove the appropriate entry in the managed node’s

nodeinfo

file. Then manually restart the ITO agents.