Chapter 10

395

Tuning, Troubleshooting, Security, and Maintenance

Troubleshooting: Specific Problems

ITO Server Problems and Solutions

Problem

The ITO management server status is completely corrupted, even after
the

ovstop opc

and

ovstart opc

sequence.

Description

Lots of corrupted messages in the message browser; lots of critical ITO
error messages, ITO agents on managed nodes cannot be stopped/started,
configuration distribution does not work, and so forth. Despite these
symptoms,

opcsv -status

may report that not all ITO manager

processes are correctly operating.

Solution

Perform the following steps:

1. Stop all ITO GUIs that are running, by exiting the ITO user interface

([File: Exit]).

2. Stop the ITO management server processes:

/opt/OV/bin/ovstop opc ovoacomm

3. Erase all ITO temporary files:

rm -f /var/opt/OV/share/tmp/OpC/mgmt_sv/*

Note that all pending messages (not yet saved in the database) and all
pending actions (automatic actions, operator-initiated actions,
scheduled actions, command broadcast) will be lost.

4. Restart the ITO management server process:

/opt/OV/bin/OpC/opcsv -start

5. Restart the ITO GUIs:

opc