beautypg.com

Hp-ux 10.x managed nodes:troubleshooting – HP UX B6941-90001 User Manual

Page 413

background image

Chapter 10

413

Tuning, Troubleshooting, Security, and Maintenance

Troubleshooting: Specific Problems

Table 10-4

Clean-up and Restart of ITO Agents on HP-UX 10.x/11.x
Managed Nodes

a. If the managed node is also the ITO management server, stop the

ITO user interfaces and manager services. To do this: 1. Check that
all ITO GUIs are terminated (

ps -eaf | grep opcui

). If they are

not, terminate them using the [File: Exit] or (Ctrl+E) functions on
any HP OpenView submap owned by ITO or use the

kill(1)

com-

mand. 2. Stop the server processes:

ovstop opc ovoacomm

b. If the managed node is also the ITO management server, restart the

ITO user interfaces and manager services, too:

ovstart opc

ovoacomm

Task

HP-UX 10.x and 11.x Managed Nodes

1. Stop ITO agents, including
the control agent:

/opt/OV/bin/OpC/opcagt -kill

2. Check that all ITO agents
are stopped.

a

/opt/OV/bin/OpC/opcagt -status

3. Check the list of agent
PIDs given by the

opcagt

-status

command. If any

PIDs are not stopped, use the

kill (1M)

command. Do not

kill the ITO Kernel Message
Logger

opckmsg

if running

on the managed node.

ps -eaf | grep opc kill

4. Check that no ITO
processes are still registered
with the

llbd

or

dced/rpcd

daemons.

/usr/sbin/ncs/lb_admin

/opt/dce/bin/rpccp or

/opt/dce/bin/dcecp

5. Remove temporary ITO
files.

rm -f /var/opt/OV/tmp/OpC/*

6. Restart ITO agents.

b

/opt/OV/bin/OpC/opcagt -start