MP5020.x

7 data bits (ASCII code, 8th bit = parity): Bit 0 = 0

8 data bits (ASCII code, 9th bit = parity): Bit 0 = 1

Block Check Character (BCC) any: Bit 1 = 0

Block Check Character (BCC) control character not permitted: Bit 1 = 1

Transmission stop through RTS active: Bit 2 = 1

Transmission stop through RTS inactive: Bit 2 = 0

Transmission stop through DC3 active: Bit 3 = 1

Transmission stop through DC3 inactive: Bit 3 = 0

Character parity even: Bit 4 = 0

Character parity odd: Bit 4 = 1

Character parity undesired: Bit 5 = 0

Character parity desired: Bit 5 = 1

Number of stop bits that are transmitted at the end of a character:

1 stop bit: Bit 6 = 0

2 stop bits: Bit 6 = 1

1 stop bit: Bit 7 = 1

1 stop bit: Bit 7 = 0
Example:
Use the following setting to adjust the TNC interface EXT2 (MP 5020.1) to

an external non-HEIDENHAIN device:
8 data bits, any BCC, transmission stop through DC3, even character

parity, character parity desired, 2 stop bits
Input for MP 5020.1: %01101001

Interface type for EXT1 (5030.0) and
EXT2 (5030.1)

MP5030.x

Standard transmission: 0

Interface for blockwise transfer: 1

Touch probes

Selecting signal transmission

MP6010

Touch probe with cable transmission: 0

Touch probe with infrared transmission: 1

Probing feed rate for triggering touch
probes

MP6120
1

to 3000 [mm/min]

Maximum traverse to first touch point

MP6130
0.001

to 99 999.9999 [mm]

Safety clearance to probing point during
automatic measurement

MP6140
0.001

to 99 999.9999 [mm]