Placing the fixture on the machine

Call the fixture management

Select the fixture: The TNC opens the menu for fixture

selection and shows in the left window all fixtures

available in the active directory. Once you selected a

fixture, the TNC displays a graphic preview in the right

window to assist you in selecting the correct fixture.

Fixtures have the file name extension CFX

In the left window, use the mouse or arrow keys to

select a fixture. In the right window the TNC shows a

preview of the respectively selected fixture

Load fixture: The TNC calculates the required

sequence of measurement

and displays it in the left

window. In the right window it shows the fixture.

Measurement points are marked with a colored

datum symbol on the fixture. In addition, there is a

sequence of numbers to show you the order for

measuring the fixture

Start the measurement process: The TNC shows a

soft-key row with permitted scanning functions for

the respective measuring process

Select the required probing function: The TNC is in the

menu for manual probing. Description of the probing

functions: See "Overview", page 610

At the end of the probing process the TNC displays

the measured values

Load the measured values: The TNC ends the

measuring process, checks it off in the measurement

sequence and places the highlight on the subsequent

task

If input of a value is required in the respective fixture,

the TNC shows a highlight at the lower end of the

screen. Enter the requested value, e.g. jaw width of a

vise, and confirm with the ACCEPT VALUE soft key

When all measuring tasks are checked off by the TNC,

complete the measuring process with the

COMPLETE soft key

Insert a touch probe before you place a fixture!

The sequence of measurement is specified in the fixture

template. You have to run through the sequence of

measurements step by step from top to bottom.
With multiple setup you have to place each fixture

separately.