FN 27: TABWRITE: Writing to a freely definable
table

After you have opened a table with FN 26: TABOPEN, you can use the

function FN 27: TABWRITE to write to it.
You can define and write in up to 8 column names in a TABWRITE

block. The column names must be written between quotation marks

and separated by a comma. You define the values that the TNC is to

write to the respective column with Q parameters.

Example:
You wish to write to the columns “Radius,” “Depth” and “D” in line

5 of the presently opened table. The values to be written to the table

must be saved in the Q parameters Q5, Q6 and Q7.

Note that by default the FN 27: TABWRITE function writes

values to the currently open table also in the Test Run

mode. Using the FN17 ID990 NR2 IDX16=1 function you can

specify that the TNC performs the FN27 function only in the

Program Run modes.
You can write only to numerical table fields.
If you wish to write to more than one column in a block,

you must save the values under successive Q parameter

numbers.

53 FN0: Q5 = 3.75

54 FN0: Q6 = -5

55 FN0: Q7 = 7.5

56 FN 27: TABWRITE 5/“RADIUS,DEPTH,D“ = Q5