beautypg.com

9 workpiece presetting with a touch probe, Overview, Workpiece presetting in any axis – HEIDENHAIN iTNC 530 (60642x-04) User Manual

Page 610: Overview workpiece presetting in any axis

background image

610

Manual Operation and Setup

14.9 W

or

k

piece pr

eset

ting with a t

o

uc

h pr

obe

14.9 Workpiece presetting with a

touch probe

Overview

The following soft-key functions are available for setting a preset on an

aligned workpiece:

Workpiece presetting in any axis

To select the touch probe function, press the

PROBING POS soft key

Move the touch probe to a position near the touch

point

Use the soft keys to select the probe axis and

direction in which you want to set the preset, such as

Z in direction Z–

Start the probing procedure: Press the NC Start button

Datum

: Enter the nominal coordinate and confirm your

entry with the SET DATUM soft key, or write the

value to a table (see "Writing the measured values

from touch probe cycles to datum tables", page 598,

or see "Writing the measured values from touch

probe cycles in the preset table", page 599, or see

"Storing measured values in the pallet preset table",

page 600)

To terminate the probe function, press the END key

Soft key

Function

Page

Presetting in any axis

Page 610

Setting a corner as preset

Page 611

Set a circle center as preset

Page 612

Center line as preset

Page 613

Danger of collision!

Note that during an active datum shift the TNC always

bases the probed value on the active preset (or on the

preset most recently set in the Manual operating mode),

although the datum shift is included in the position display.

Y

X

Z