7 checking and changing q parameters, Procedure – HEIDENHAIN iTNC 530 (60642x-04) User Manual
Page 330
330
Programming: Q Parameters
9.7 Chec
king and c
h
anging Q par
a
met
e
rs
9.7 Checking and changing Q
parameters
Procedure
You can check and edit Q parameters when writing, testing and
running programs in the Programming and Editing, Test Run, Program
Run Full Sequence, and Program Run Single Block modes.
If you are in a program run, interrupt it if required (for example, by
pressing the machine STOP button and the INTERNAL STOP soft
key). If you are in a test run, interrupt it
To call Q parameter functions: Press the Q key or the
Q INFO soft key in the Programming and Editing
mode of operation
The TNC lists all parameters and their current values.
With the arrow keys or the soft keys, go pagewise to
the desired parameters
If you would like to change the value, enter a new
value and confirm with the ENT key
To leave the value unchanged, press the PRESENT
VALUE soft key or end the dialog with the END key.
The parameters used by the TNC internally or in cycles are
provided with comments.
If you want to check or edit local, global or string
parameters, press the SHOW PARAMETERS Q QL QR QS
soft key. The TNC then displays all respective parameters
and the above described also apply.