9.7 Checking and changing Q

parameters

Procedure

You can check and edit Q parameters when writing, testing and

running programs in the Programming and Editing, Test Run, Program

Run Full Sequence, and Program Run Single Block modes.

If you are in a program run, interrupt it if required (for example, by

pressing the machine STOP button and the INTERNAL STOP soft

key). If you are in a test run, interrupt it

To call Q parameter functions: Press the Q key or the

Q INFO soft key in the Programming and Editing

mode of operation

The TNC lists all parameters and their current values.

With the arrow keys or the soft keys, go pagewise to

the desired parameters

If you would like to change the value, enter a new

value and confirm with the ENT key

To leave the value unchanged, press the PRESENT

VALUE soft key or end the dialog with the END key.

The parameters used by the TNC internally or in cycles are

provided with comments.
If you want to check or edit local, global or string

parameters, press the SHOW PARAMETERS Q QL QR QS

soft key. The TNC then displays all respective parameters

and the above described also apply.