Determining basic rotation using 2 holes/studs – HEIDENHAIN iTNC 530 (60642x-04) User Manual

Page 608

background image

608

Manual Operation and Setup

14.8 Compensating w

o

rk

piece misalignment with a 3-D t

o

uc

h pr

obe

Determining basic rotation using 2 holes/studs:

Select the probe function by pressing the PROBING

ROT soft key (soft-key row 2)

Circular studs are to be probed. Define by soft key

Holes are to be probed. Define by soft key

Probing holes
Pre-position the touch probe approximately in the center of the hole.

After you have pressed the NC Start key, the TNC automatically

probes four points on the wall of the hole.
Move the touch probe to the next hole, repeat the probing operation

and have the TNC repeat the probing procedure until all the holes have

been probed to set reference points.

Probing cylindrical studs
Position the touch probe at a position near the first touch point of the

stud. Select the probing direction by soft key and press the machine

START button to start probing. Perform the above procedure four

times.

Saving the basic rotation in the preset table

After the probing process, enter the preset number in which the

TNC is to save the active basic rotation in the Number in table:

input box

Press the ENTRY IN PRESET TABLE soft key to save the basic

rotation in the preset table