beautypg.com

8 a d ditional functions – HEIDENHAIN iTNC 530 (60642x-04) User Manual

Page 351

background image

HEIDENHAIN iTNC 530

351

9.8 A

d

ditional functions

The following conditions are permitted in the FN 20 block:

In addition, the FN20: WAIT FOR SYNC function is available. WAIT FOR
SYNC

is used whenever you read, for example, system data via FN18

that require synchronization with real time. The TNC stops the look-

ahead calculation and executes the subsequent NC block only when

the NC program has actually reached that block.

Example: Stop program run until the PLC sets marker 4095 to 1

Example: Pause internal look-ahead calculation, read current
position in the X axis

condition

Short designation

Equal to

==

Less than

<

Greater than

>

Less than or equal

<=

Greater than or equal

>=

32 FN 20: WAIT FOR M4095==1

32 FN 20: WAIT FOR SYNC

33 FN 18: SYSREAD Q1 = ID270 NR1 IDX1