1.2 Machine switch-on

Acknowledging the power interruption and
moving to the reference points

Switch on the power supply for control and machine. The TNC starts

the operating system. This process may take several minutes. Then

the TNC will display the message "Power interrupted" in the screen

header

Press the CE key: The TNC compiles the PLC program

Switch on the control voltage: The TNC checks

operation of the emergency stop circuit and goes into

the reference run mode

Cross the reference points manually in the displayed

sequence: For each axis press the machine START

button. If you have absolute linear and angle encoders

on your machine there is no need for a reference run

The TNC is now ready for operation in the Manual Operation mode.

Further information on this topic

Traversing the reference marks: See "Switch-on", page 564

Operating modes: See "Programming and Editing", page 83

Switch-on and crossing the reference points can vary

depending on the machine tool. Your machine manual

provides more detailed information.