beautypg.com

Copying system data to a string parameter, 1 0 str ing par a met e rs – HEIDENHAIN iTNC 530 (60642x-04) User Manual

Page 361

background image

HEIDENHAIN iTNC 530

361

9.1

0

Str

ing par

a

met

e

rs

Copying system data to a string parameter

The SYSSTR function copies system data to a string parameter. At

present only reading of the system time is available.

Select Q-parameter functions

Select the STRING FORMULA function

Enter the number of the string parameter in which the

TNC is to save the copied string. Confirm with the

ENT key

Select the function for copying system data

Enter the Number of the system key (ID321 for the

system time) that you want to copy, and confirm with

the ENT key

Enter the Index for system key. It defines the format

for the system time to be output. Confirm with the

ENT key (see description below)

Array index of the source to be read

has no

function yet. Confirm with the NO ENT key

Number to be converted to text

has no function yet.

Confirm with the NO ENT key

Close the parenthetical expression with the ENT key

and confirm your entry with the END key

This function is prepared for future expansions. The

parameters IDX and DAT currently have no function.