beautypg.com

5 workpiece presetting without a touch probe, Note, Preparation – HEIDENHAIN iTNC 530 (60642x-04) User Manual

Page 587: Note preparation

background image

HEIDENHAIN iTNC 530

587

14.5 W

o

rk

piece pr

eset

ting without a t

o

uc

h pr

obe

14.5 Workpiece presetting without a

touch probe

Note

You fix a preset by setting the TNC position display to the coordinates

of a known position on the workpiece.

Preparation

Clamp and align the workpiece

Insert the zero tool with known radius into the spindle

Ensure that the TNC is showing the actual position values

Workpiece presetting with a touch probe: (see page 610)