Enterasys Networks CSX6000 User Manual
Page 593
Central Site Remote Access Switch 593
S
YSTEM
C
OMMANDS
Call Control Commands
To use this command for troubleshooting, you must use the System Call Trace feature to
capture any connect and disconnect messages that are generated by issuing the
call device
command. To do this:
1.
Erase the current report log by entering
er
at the system prompt.
2.
Enable the Call Trace feature by entering
trace on
at the system prompt.
3.
Issue the
call device
command.
4.
Display the system log messages by entering the
dr
command at the system prompt.
5.
Check the log report for connect messages relating to the remote device you are testing.
In response to the
call device
command, one of the following responses
will be displayed:
Calling device
Indicates that a call request process has been initiated.
Indicates that the device name could not be found in the table of configured device names.
Indicates that a connection to a device can not be initiated if there is already a connection
to that device. The call device command cannot be used to increase bandwidth for an
existing connection.
Call attempt failed
Indicates that the request could not be executed.
More than one match for
Displayed if you enter just part of a device name and that part could specify more than one
device name. You will be prompted to enter the device name again, in a more specific
manner. For example, if
call device Sch
is entered, and there is a device configured
with the name Schultz, and a device configured with the name Schmidt, this message
would be displayed. You would then need to enter at least
call device Schu
to
successfully initiate a call to the device Schultz.
Each PPP device in the device database can have one or two phone numbers at which they
can be called. This message is displayed if the device has no phone number specified.
Re-enter the name, or
The device name must be re-entered.