beautypg.com

Enterasys Networks CSX6000 User Manual

Page 541

background image

Central Site Remote Access Switch 541

S

YSTEM

M

ESSAGES

System Message Summary

X25 facilities error, bad facility length
The facilities length is missing. Contact your Distributor or Customer Support.

X25 facilities error, invalid facilities length
The length of the facilities packet is invalid. Contact your Distributor or Customer Support.

X25 facilities error, invalid DTE address
The supplied address in a X.25 call packet was invalid. Verify that the local DTE address
configuration matches the address supplied by the service provider.

X25 facilities error, facility not allowed
A facility was requested which is not enabled. Verify that the specific facility is enabled by both
DTE’s and the service provider.

X25 facilities error, facility length too short
The length of the facilities packet is too short. Contact your Distributor or Customer Support.

X25 facilities error, invalid facilities parameter
A value was chosen for facility which is out of the acceptable range of values for that facility. The
range of acceptable values for that facility should be verified at both DTE’s and by the service
provider.

X25 facilities error, reverse charging not allowed
The reverse charging facility was selected by the DTE. Verify that reverse charging is enabled by
both DTE’s and the service provider.

X25 facilities error, reverse charging not accepted
The reverse charging facility was selected by the DTE. Verify that reverse charging is enabled by
both DTE’s and the service provider.

X25 facilities error, fast select not available
The fast select facility was selected by the DTE. Verify that fast select is enabled by both DTE’s and
the service provider.

X25 facilities error, fast select not accepted
The fast select facility was selected by the DTE. Verify that fast select is enabled by both DTE’s and
the service provider.

X25 facilities error, throughput negotiation not allowed
The DTE throughput class does not match the throughput class available at either the DCE or the
remote DTE, and throughput negotiation is not enabled. You should enable throughput
negotiation at both DTE’s. If this is not possible, or does not work, select the same throughput class
at both DTE’s.

X25 facilities error, closed device group not allowed
The closed device group facility was selected by the DTE. Verify that the closed device group
facility is enabled by both DTE’s and the service provider.

X25 facilities warning, reverse charging info not available
The service provider does provide reverse charging information. No action required.

This manual is related to the following products: