Enterasys Networks CSX6000 User Manual
Page 408
USER’S GUIDE
408 CyberSWITCH
E
VENT
T
YPE
This field indicates what type of event the associated message is reporting. The possible values are
‘CONNECT’, ‘DISCONNECT’, ‘REJECT’,’TERM CONN’,’TERM DISC’,’TERM SUCC’,’TERM
FAIL’, ‘SYSTEM UP’ and ‘CDR VERIFY’.
NAS N
AME
NAS Name (Network Access Server Name) contains the System Name of the system logging the
message.
P
HONE
N
UMBER
On incoming calls this field contains the Calling Line Id of the caller if the information is available
(some switches do not provide Calling Line Id). On outgoing calls, this field contains the phone
number of the remote device that the system is calling.
R
EMOTE
D
EVICE
N
AME
This field contains the name of the remote device, if available.
S
LOT
, L
INE
AND
B
EARER
This field identifies the slot (or resource), the line and the bearer channel used for the associated
connection.
T
IME
STAMP
The field contains the time and date. The meaning of this field varies depending upon the report.
Connect/Term Connect Event Report Contents
On a connect event, records 1 through 3 are used. The event type is CONNECT or TERM CONN.
The time stamp reflects the time that the ISDN connect message was received from the switch. An
incoming phone number is displayed if it is provided by the telephone switch. Not all switches
provide calling line identification. A phone number is always displayed for outbound calls.
example 1:
Chicago-Schaumburg 00000001 CONNECT 1 OF 3 MonroeCounty PORT 1/1/1
Chicago-Schaumburg 00000001 CONNECT 2 OF 3 IN FROM 3135551212
Chicago-Schaumburg 00000001 CONNECT 3 OF 3 64Kb 08/28/97 23:11:55
example 2:
Chicago-Schaumburg 00000001 CONNECT 1 OF 3 MonroeCounty PORT 1/1/1
Chicago-Schaumburg 00000001 CONNECT 2 OF 3 OUT TO 3135551212
Chicago-Schaumburg 00000001 CONNECT 3 OF 3 64Kb 08/28/97 23:11:55
Note:
In most cases, a device is identified when a connect event occurs and the device name is
included in the connect report. With user level security, the connect event occurs before the
user is identified. Therefore, the connect report will contain a name of UNKNOWN. The
disconnect report will have the actual user name, as determined by SENTRY. The
connection Id from the connect and disconnect reports will match.
Disconnect/Term Disconnect Event Report Contents
On a disconnect event, records 1 through 4 are used. The event type is DISCONNECT or TERM
DISC. The time stamp reflects the time that the decision to disconnect was made. The phone
number displayed is the phone number that was used to dial out, or the incoming calling line id
(depending on call direction).