USER’S GUIDE
202 CyberSWITCH
Bridging with PPP Bridge Devices (Using BCP)
To allow a PPP Bridge device to connect to the CyberSWITCH, you must have Bridging enabled.
For each PPP Bridge device using this type of connection, you may need to enter a PAP Password
or a CHAP Secret, and a Calling Line Id.
The following table identifies the configuration requirements for possible security options for PPP
Bridge Devices.
Note:
If CHAP Security is enabled, and Outbound Authentication has not been disabled, a CHAP
Secret must be entered for both the remote device and for the CyberSWITCH. Refer to the
for information regarding the System Secret. If Outbound
Authentication has been disabled, a CHAP Secret is not required for the remote device.
IP Routing with PPP Bridge Devices (Using BCP)
To allow devices to connect to the CyberSWITCH using IP routing through a PPP Bridge device,
you must configure a RLAN IP Network Interface. IP routing must also be enabled. For each PPP
Bridge using this type of connection, you may need to enter the Device Name, a Calling Line Id, a
PAP Password or a CHAP Secret, and an IP (Sub) Network Number.
Security Mode Configuration
On-node Device Table Configuration
Data
Calling Line Id
PAP or CHAP
Security
Calling Line Id
PAP Password or
CHAP Secret
Disabled
Enabled
Not Requested
Required
Enabled
Enabled
Optional per
device entry
Required
Enabled
Disabled
Required
Optional