X.25 and a terminal server menu, X.25 and a terminal server menu 432 – Enterasys Networks CSX6000 User Manual
Page 432
![background image](/manuals/79701/432/background.png)
USER’S GUIDE
432 CyberSWITCH
c.
Wait 20 seconds, then enter the
dr
command to display the report log. The status log
should display a sequence of the following messages:
(I) 17:33:35.38 #1067: Out - LAPB RR, Rx Sequence = 1
(I) 17:33:35.38 #0000: 01 31 00 2A
(I) 17:33:35.38 #1067: IN - LAPB RR, Rx Sequence = 1
(I) 17:33:35.38 #0000: 01 31 A2 00
d. If these messages are not displayed, verify with the service provider that the line and
bearer are provisioned for X.25 packet access, and the LAPB addressing format, modulo 8
or 128, is consistent with the line provisioning.
e.
If the log contains a sequence similar to the following:
(I) 17:33:32.32 #1067: IN - LAPB SABM
(I) 17:33:42.32 #1067: IN - LAPB SABM
(I) 17:33:52.32 #1067: IN - LAPB SABM
verify with the service provider verify that the line and bearer are provisioned for X.25
packet access, and the LAPB addressing format, modulo 8 or 16, is consistent with the line
provisioning.
f.
If the log contains a sequence similar to the following:
(I) 17:33:32.32 #1067: IN - LAPB SABM
(I) 17:33:32.32 #0000: 03 3F A6 04
(I) 17:33:32.32 #1C05: x25 access 1 in state ACCESS UP for
event LAPB UP
(E) 17:33:32.32 #1C04: Invalid event for access 1
(I) 17:33:32.32 #1C05: x25 access 1 in state ACCESS UP for
event X25 DOWN
(I) 17:33:32.32 #1067: Out - LAPB UA
(I) 17:33:32.32 #0000: 03 73 00 10
verify that the LAPB timer values are consistent with the service provider specifications.
X.25
AND
A
T
ERMINAL
S
ERVER
M
ENU
1.
If the CyberSWITCH is dialed, but the remote user does not get a menu, check configuration.
Verify that Use Menu for Authentication is selected (Security, Network Login, General
Configuration, Terminal Server Security).
2.
If the CyberSWITCH is dialed and the modem connects, but the remote user does not get a
menu or pad prompt, and then soon disconnects, check configuration. Verify that X.3 PAD is
enabled (Options).
3.
If the connection is made to the CyberSWITCH, and the menu/pad prompt is displayed, but
keystrokes are not echoed: Verify correct pad parameter settings for non-transparent pad
profile.