Enterasys Networks CSX6000 User Manual
Page 497
Central Site Remote Access Switch 497
S
YSTEM
M
ESSAGES
System Message Summary
[DHCP-R] Failed to close UDP port (67), erc =
Mode. Contact your Distributor or Customer Support.
[DHCP-R] Failed to open UDP port (67), erc =
the BOOTPS UDP port in order to operate successfully. If this port could not be opened, the Relay
Agent will not be enabled. Contact your Distributor or Customer Support.
[DHCP-R] Relay Agent disabled
The DHCP Relay Agent has been successfully disabled. This message will appear if the user
disabled the Relay Agent from Manage Mode.
[DHCP-R] Relay Agent enabled
The DHCP Relay Agent has been successfully enabled. This could be during system initialization
(if configuration values have enabled it), or after the DHCP Relay Agent has been enabled from
Manage Mode.
[DHCP-R] Relay Agent initialization failed
This message indicates that the DHCP Relay Agent did not initialize successfully. The Relay Agent
will not be operational. Contact your Distributor or Customer Support.
[DHCP-R] UDP port (67) closed
The DHCP Relay Agent is being disabled from Manage Mode and it must close the BOOTPS UDP
port (port 67). If the DHCP Proxy Client is also enabled, the BOOTPS port must remain open. In
this case, the DHCP Relay Agent will not close the UDP port.
[DHCP-R] UDP port (67) opened
The DHCP Relay Agent is being enabled and it must open the BOOTPS UDP port (port 67). This
may occur during system initialization, or after the DHCP Relay Agent has been enabled from
Manage Mode. If the DHCP Proxy Client is also enabled, it may not be necessary for the Relay
Agent to open this UDP port.
Dial Out Device does not have Bridge Callable Enabled
Check configuration. Enable the Make Calls for Bridge Data field under Device Table Menu, Bridging.
Discrepancy in dynamically-obtained device data
The System authentication type is configured to obtain device information off-node. In an
outbound call scenario with security enabled, two transactions may occur for the same device. If
these do not yield the same information, the call is dropped. Contact your Distributor or Customer
Support.
DL
for further information (
dr
command).
DM card in slot
state. Contact your distributor or Customer Support. You most likely need to replace or upgrade
the firmware on the Digital Modem.