Modem inactivity timeout background information – Enterasys Networks CSX6000 User Manual

Page 388

background image

USER’S GUIDE

388 CyberSWITCH

M

ODEM

I

NACTIVITY

T

IMEOUT

B

ACKGROUND

I

NFORMATION

The Modem Inactivity Timeout feature allows the CyberSWITCH to terminate connections to
digital modem devices based on a lack of data transfer for a specified amount of time. This feature
applies to both incoming and outbound calls.

The Modem Inactivity Timeout feature supports DM-24, DM-24+ and DM-30+ modem adapters
only, on CyberSWITCH systems running UAA software release 7.3 or beyond. The feature is not
supported for DM-8 adapters. When you configure a value for the Modem Inactivity Timeout, that
value will then apply to all qualified modems resident on the CyberSWITCH.

Unlike the

Throughput Monitor

, any activity whatsoever (transmitted or received) will keep a call

up and restart the Modem Inactivity Timer. If you wish to limit the duration of calls regardless of
traffic, use

Call Restrictions

or

CSM Manager

.