The following pages list all the informational, warning and error messages alphabetically. The text
describes the messages, and includes suggestions for problem resolution (if applicable). Note that
the trace messages have been isolated for your convenience, and are summarized in the next
chapter.

# 000: Couldn’t open the file C:\SYSTEM\PLATFORM.NEI
The open operation failed, no further detail is available.

# 0000: Error reading C:\SYSTEM\PLATFORM.NEI
The read operation failed, perform a software upgrade to reinstall the file.

# 0000: Error reading platform type: there is no “plat name” field
There is no value following the “=” character in the “current setting” string.

# 0000: Error reading platform type: there was no “=” in the string
The “current setting” string has the format “=”. This error message
indicates that no “=” character exists in the string.

# 0000: Error reading platform type: type value is too large
The value in the “current setting” string is too large to represent an actual platform
type.

# 0000: Error reading platform type: type was not converted to an int
The value in the “current setting” string could not be converted to an actual
platform type.

1 port LAN Adapter, operating in remote mode only
This is an initialization message. It identifies the Ethernet adapter type (Ethernet-1), and operating
mode. Remote bridging is supported.

2 port LAN Adapter, operating in local and remote mode
This is an initialization message. It identifies the Ethernet adapter type (Ethernet-2), and operating
mode. Both local and remote bridging are supported.

aarp found duplicate AppleTalk address @
The address resolution protocol found duplicate AppleTalk addresses for this AppleTalk network.
Check the configuration for the AppleTalk ports’ network range/number.

Abnormal response rcvd:
An unexpected message was received from a WAN interface card. The included are
for problem reporting purposes only. If the system fails to operate normally, or the warning
continues to occur, contact your Distributor or Customer Support.

A call has exceeded the configured maximum duration
A call has been up longer than the amount of time configured. The next log message will inform
the user whether or not the call has been taken down.