4.4 SNMP Trap
Port 2
This parameter determines the SNMP Trap Port used for sending destination #2 trap
messages. UDP Port 162 is the default used for SNMP trap messages. However, if this
port is being used by another protocol or service, you can change the setting by
modifying this parameter. This parameter is available only if parameter 4.0 SNMP
Enable is set to On.
5 Power Supply
Alarm
This parameter controls how the FS2 alarm responds to power supply
disconnection or failure. By default (Normal) the alarm is triggered anytime either of
the two internal power supplies fails or is disconnected from a power source
(becomes unplugged). If the FS2 will be connected using only one power cord and
supply, you can suppress the alarm. The ADJUST knob changes the setting, and the
change is automatically saved.
6.1 Vid1 Format
Alarm
When set to Normal (default), an alarm is triggered whenever the selected input
video signal format of Video Proc 1 is incompatible with the selected output format
(refer to the matrix of inputs and compatibilities presented in Chapter 2). If you want
the FS2 alarm to only trigger on hardware failures, you can suppress the Format
Alarm. The front panel Vid 1 FMT ERR LED lights when format errors are detected
even if this parameter is set to Suppress. The ADJUST knob changes the setting, and
the change is automatically saved.
4.4 SNMP Trap Port 2
Selections
Selection Descriptions
Parameter
Adjustments:
variab
Variable
Turn the ADJUST knob to select a UDP port for sending FS2 trap messages.
Default: 162
5 Power Supply Alarm
Selections
Selection Descriptions
Normal (default)
Suppress
Alarm triggers if either internal power supply experiences a failure or is
disconnected from mains power.
Alarm will not be triggered by a power supply failure or disconnection
from power.
6.1 Vid 1 Format Alarm
Selections
Selection Descriptions
Normal (default)
Suppress
Alarm triggers if the format of the selected input video signal is
incompatible with the selected output format.
Alarm will not be triggered by a format incompatibility.