REMOTE Menu Group

The REMOTE Menu Group lets you set up how you want the FS2 to be controlled.
Control options include the front panel, a remote computer running a browser, a
remote control panel, and GPI inputs and outputs.

1 Remote
Control

This parameter determines how the FS2 panel responds to controls locally from the
front panel and from a network attached computer with a web browser (or both). The
selected mode is indicated by the color of the REMOTE LED. (Note: the REMOTE LED
and other front panel indicators are described in Chapter 2.)

1.1
Authentication

This parameter enables or disables an authentication login requirement. By default
this parameter is set to Disabled.

When you select Login via the front panel parameter, you must then go to the
browser interface to perform a login each time you access the FS2. The browser
presents the login screen first, requiring you to log in before you can access any other
browser screens. The password is initially set to the default value, but you can change
it using the Remote browser screen. The default password is password.

Note: If authentication is used, it provides only a minimum security safeguard
against unauthorized use of the FS2. The authentication mechanism is simple and
does not provide robust security.

1 Remote Control

Selections

Selection Descriptions

LOCAL + REMOTE (default)

LOCAL ONLY

REMOTE ONLY

Control the FS2 from the front panel, a remote control panel, or a

network-attached browser. The REMOTE LED lights amber.

Control the FS2 only from the front panel (browsers cannot change

parameters). The REMOTE LED lights green.

Control the FS2 only from a network attached browser or remote control

panel. The REMOTE LED lights red.

1.1 Authentication

Selections

Selection Descriptions

Disabled (default)

Login

Disables the requirement for a login password. No password is needed.
Login is required via the web browser interface befor e changes can be

made in FS2 configuration. The default password is “password”.