Chapter 2, Drive start up, Drive start up checklist – Rockwell Automation 20P PowerFlex Digital DC Drive User Manual
Page 87: Chapter

Rockwell Automation Publication 20P-UM001I-EN-P - February 2013
87
Chapter
2
Drive Start Up
This chapter describes how to start up the PowerFlex DC drive. If using the LCD
HIM (Human Interface Module) to commission the drive, it is recommended
that you read
before performing these procedures.
Drive Start Up Checklist
This checklist contains the major steps required to complete the drive
commissioning procedure.
❏ Verify all Drive Configuration Settings -
❏ Verify the Power Wiring -
❏ Verify the Control and I/O Wiring -
.
❏ Apply Voltage to the Control Circuits -
.
❏ Verify the Control Voltages -
.
❏ Load the Default Settings -
❏ Configure the Most Commonly Used Parameters -
.
❏ Tune the Current Regulator -
.
❏ Verify Motor Rotation and Run Feedback Polarity Checks -
.
❏ Configure the Speed Feedback Parameters -
.
.
❏ Verify Speed Reference Settings and Drive Operation -
ATTENTION: Power must be applied to the drive to perform the following start-
up procedure. Some of the voltages present are at incoming line potential. To
avoid electric shock hazard or damage to equipment, only qualified service
personnel should perform the following procedure. Thoroughly read and
understand the procedure before beginning. If an event does not occur while
performing this procedure, Do Not Proceed. Remove Power including user
supplied control voltages. Correct the malfunction before continuing.
IMPORTANT
It is recommended that you uncouple the motor from all loads at this time,
until otherwise directed.