Rockwell Automation 20P PowerFlex Digital DC Drive User Manual
Page 122

122
Rockwell Automation Publication 20P-UM001I-EN-P - February 2013
Chapter 3
Programming and Parameters
MO
NIT
OR
Cu
rrent Met
ers
232
[Inertia Comp Out]
Displays the output of the Inertia Compensation function. The [Inertia Comp
Out] signal (if selected by Par 1016 [SpdFuncSelect]) is summed with Pars 14
[Selected TorqRef] and 40 [Trim Torque]. Inertia compensation provides a
torque feed forward signal during changes in motor speed reference.
Note: This parameter was added for firmware version 4.001.
Default:
Min/Max:
Units:
Read Only
–/+200
%
Real
234
[Fld Current Pct]
Field current (present value) as a percentage of Par 280 [Nom Mtr Fld Amps].
When running a permanent magnet motor, this parameter will display zero.
Note: This parameter can be assigned to an analog output and is the default
value for Par 68 [Anlg Out3 Sel].
Default:
Min/Max:
Units:
Read Only
0.00 / 100.00
%
Real
280
236
[Spd Reg Out Pct]
Output value of the speed regulator, as a percentage of Par 179 [Nom Mtr
Arm Amps], used as the reference for the current regulator.
Default:
Min/Max:
Units:
Read Only
–/+250
%
Real
179
351
[Field Current]
Present value of the field current. When running a permanent magnet motor,
this parameter will display zero.
Note: This parameter can be assigned to an analog output.
Default:
Min/Max:
Units:
Read Only
0.00 / 99.90
A
Real
476
[Field Curve Out]
Displays the output value of the field current used as a reference to the field
current regulator.
Note: This parameter was added for firmware version 4.001.
Default:
Min/Max:
Units:
Read Only
0.00 / 100.00
%
Real
500
[Flux Ref Pct]
Field flux (reference) as a percentage of Par 280 [Nom Mtr Fld Amps]. When
running a permanent magnet motor, this parameter will display zero.
Notes: This parameter can be assigned to an analog output. This name of this
parameter was changed from [Field Ref Pct] for firmware version 3.001.
Default:
Min/Max:
Units:
Read Only
0.00 / 100.00
%
Real
280
928
[Filt TorqCur Pct]
Filtered value of Par 1193 [Torq Current Pct]. The amount of filtering is set by
Par 926 [Torq Cur Filter].
Default:
Min/Max:
Units:
Read Only
–/+250
%
16-bit
Int
926,
1193
Dr
iv
e Da
ta
57
[FaultCode]
A code that represents the fault that tripped the drive. See Fault Descriptions
on page
for a list of fault codes and descriptions.
Default:
Min/Max:
Read Only
0 / 65535
16-bit
Int
233
[Output Voltage]
Measured output armature voltage.
Note: This parameter can be assigned to an analog output and is the default
selection for Par 69 [Anlg Out4 Sel].
Default:
Min/Max:
Units:
Read Only
-/+999.00
Vdc
Real
235
[Elapsed Lifetime]
Shows the operating time of the drive. This parameter counts the time for
which the drive is energized (even if the drive is disabled).
Default:
Min/Max:
Units:
Read Only
0.00 / 65535.0
H.m
Real
300
[Drive Type]
Displays of the drive type.
“10” = Non-Regenerative
“11” = Regenerative
Default:
Min/Max:
Read Only
10 / 11
16-bit
Int
331
[Software Version]
Displays the Major and Minor (Major.Minor) firmware version numbers active
in the drive.
Default:
Min/Max:
Read Only
1.00 / 999.00
Real
465
[Drive Size]
Armature current rating (as indicated by the configuration of DIP switch S15
on the control board). This value is used to determine the Drive Overload fault
(F64).
Note: S15 is set to the appropriate value at the factory. However, if the control
board was supplied separate from the drive and installed as a replacement
part, S15 must be manually set to the appropriate drive size. See DIP Switch
and Jumper Settings on page
Default:
Min/Max:
Units:
Read Only
0 / Based on drive current rating
A
16-bit
Int
Fil
e
Gr
oup
No
.
Parameter Name & Description
See
page 110
for symbol descriptions
Values
Da
ta
T
yp
e
Rela
ted