Rockwell Automation 20P PowerFlex Digital DC Drive User Manual
Page 216
216
Rockwell Automation Publication 20P-UM001I-EN-P - February 2013
Appendix A
Supplemental Drive Information
Table 44 - Frame C Drives Watts Loss and Fan Capacity
Table 45 - Frame D Drives Watts Loss and Fan Capacity
Drive
Fans
(2)
(2) Fans on frames C drives must be powered by an external 230 V AC, 50/60 Hz power supply, connected to terminals U3 and V3.
Current Rating
Code
(1)
(1) See Standard Drive Catalog Number Explanation on page
, positions 8…10 for corresponding drive Hp rating, armature amp rating
and field amp rating.
AC Input
Voltage
Total Watts
Loss
Input Voltage
(VAC)
Rated Current
(A)
Max Air Flow Capacity
Noise Level
521
230
2143
230
0.75
1050 m
3
/h
62.5 dB(A)
700
2700
495
460
2143
667
2590
540
575
2300
675
2620
452
690
1700
565
2300
Drive
Fans
(2)
(2) Fans on frames D drives must be powered by an external 230 V AC, 50/60 Hz power supply, connected to terminals U3 and V3.
Current Rating
Code
(1)
(1) See Standard Drive Catalog Number Explanation on page
, positions 8…10 for corresponding drive Hp rating, armature amp
rating and field amp rating.
AC Input
Voltage
Total Watts
Loss
Input Voltage
(VAC)
Rated Current
Max Air Flow Capacity
Noise Level
875
230 2694
230
2.4A@50Hz and
3.3A@60Hz
2400 m
3
/h
80 dB(A)
1K0
3284
830
480 3200
996R
3568
1K1
4189
1K3
5229
1K4
5117
810
575 3122
1K0
3819
1K2
4679
1K3
4879
1K6
5720
678
690 3174
791
3582
904
4028
1K0
4064
1K1
4509
1K2
5368
1K4
5543
1K5
5886