Rockwell Automation 20P PowerFlex Digital DC Drive User Manual
Page 214
214
Rockwell Automation Publication 20P-UM001I-EN-P - February 2013
Appendix A
Supplemental Drive Information
Category
Specification
Feedback
Devices
Encoder
Type: Incremental, dual channel, two channel optional (with
jumper), differential (recommended) or single-ended
Input Voltage: Configurable for +2.5V…5.2V (switch S21 in
ENC_5 position) or +5.4V…15.2V (switch S21 in ENC_12
position).
Note: The encoder must be capable of the same power supply
(input) and feedback level (output) voltage (see page
).
Input Current: 3 mA…10.9 mA each channel
Quadrature: 90
°
± 27
°
@ 25
°
C
Duty cycle: 50% ± 10% Source/Sink capable
Pulses Per Revolution: 100…32770
Maximum Frequency: 150 kHz
Maximum Cable Length: Shielded, 150m (0.75 mm
2
), 125m (0.5
mm
2
), 55m (0.22 mm
2
)
Resolver
See the PowerFlex DC Drive Resolver Feedback Option Module
Installation Instructions, publication
for details.
DC Analog Tachometer
Input Voltage: 22.7, 45.4, 90.7, 181.6, & 302.9V max.
Input Current: 8 mA full scale
Maximum Cable Length: Shielded, depends on the installation,
typical 150 m.
Inputs
Analog Inputs
Three configurable, isolated, differential
±
10V, 0-10V, 0-20 mA or 4-20 mA.
Resolution: 11 Bit + sign
Digital Inputs
Eight standard configurable, four additional configurable with the
I/O Expansion circuit board.
Max Voltage +30V DC input, 200 mA (total current draw is the
sum of encoder power, digital outputs and any other loads
connected to terminal 19)
Outputs
Analog Outputs
Two standard configurable, two additional configurable with the
I/O Expansion circuit board. Sampling rate 2 ms.
± 10V, 5mA, bipolar (current is not bipolar)
Resolution: 11 Bit + sign
Digital Outputs
Four standard configurable, four additional configurable with the
I/O Expansion circuit board.
+ 30V, 50 mA
Relay Outputs
Two configurable, N.O. contacts
Max. 250V AC, 1A AC1