Rockwell Automation 20P PowerFlex Digital DC Drive User Manual
Page 156
156
Rockwell Automation Publication 20P-UM001I-EN-P - February 2013
Chapter 3
Programming and Parameters
APP
LIC
ATIO
NS
D
iame
ter Cal
c
1162 [Diameter Filter]
Diameter calculation filter.
Default:
Min/Max:
Units:
100
0 / 5000
ms
16-bit
Int
1163 [Base Omega]
Winder speed at the maximum line speed and minimum diameter of the winder/
unwinder (motor shaft side).
Default:
Min/Max:
Units:
1500
0 / 8191
rpm
16-bit
Int
1164 [Diam Preset 0]
First preset starting diameter. The value of this parameter must be set between the
value of Pars 799 [Minimum Diameter] and 1153 [Max Diameter].
Default:
Min/Max:
Units:
1.00
0.00 / 32.00
m
Real
799,
1153
1165 [Diam Preset 1]
Second preset starting diameter. The value of this parameter must be set between
the value of Pars 799 [Minimum Diameter] and 1153 [Max Diameter].
Default:
Min/Max:
Units:
1.00
0.00 / 32.00
m
Real
799,
1153
1166 [Diam Preset 2]
Third preset starting diameter. The value of this parameter must be set between
the value of Pars 799 [Minimum Diameter] and 1153 [Max Diameter].
Default:
Min/Max:
Units:
1.00
0.00 / 32.00
m
Real
799,
1153
1167 [Diam Preset 3]
Fourth preset starting diameter. The value of this parameter must be set between
the value of Pars 799 [Minimum Diameter] and 1153 [Max Diameter]. This
parameter can be assigned to an analog input. If an analog input is used, +10V
corresponds to the value of [Max Diameter] and the voltage corresponding to the
minimum diameter = 10 x ([Minimum Diameter] / [Max Diameter]).
Default:
Min/Max:
Units:
1.00
0.00 / 32.00
m
Real
799,
1153
1168 [Diam Preset Sel]
Selects the starting diameter for the Diameter Calculation function.
• 0 = Par 1164 [Diam Preset 0]
• 1 = Par 1165 [Diam Preset 1]
• 2 = Par 1166 [Diam Preset 2]
• 3 = Par 1167 [Diam Preset 3]
This parameter can also be set via two digital inputs programmed as 57 “Diam
Preset0” and 58 “Diam Preset1”; the selection in this case is carried out with binary
logic.
Default:
Min/Max:
0
0 / 3
16-bit
Int
1164,
1165,
1166,
1167
1187 [Winder Type]
Winder/unwinder selection. If the selection is carried out via a digital input: 0V =
“Winder” , +24V = “Unwinder”.
Default:
Options:
0 =
0 =
1 =
“Winder”
“Winder”
“Unwinder”
16-bit
Int
Fil
e
Gr
oup
No
.
Parameter Name & Description
See
page 110
for symbol descriptions
Values
Da
ta
T
yp
e
Rela
ted
A
A
A
A
A
A
A
“Diam Preset1”
“Diam Preset0”
Selection
0
0
Par 1164 [Diam Preset 0]
0
1
Par 1165 [Diam Preset 1]
1
0
Par 1166 [Diam Preset 2]
1
1
Par 1167 [Diam Preset 3]
A