Figure 69, Fuses for non-regenerative frame c and d drives – Rockwell Automation 20P PowerFlex Digital DC Drive User Manual
Page 230

230
Rockwell Automation Publication 20P-UM001I-EN-P - February 2013
Appendix A
Supplemental Drive Information
Figure 69 - Frame D Regenerative Drive - Leg Fuse Location
Fuses for Non-Regenerative Frame C and D Drives
AC input line and/or leg fuses are internally mounted and provided with frames
C and D drives. See Fuse Code FS4 in
on page
for fuse locations.
Table 67 - Recommended AC Input Line Fuses - 230V AC Input Frame C Drives
Table 68 - Recommended Leg Fuses - 230V AC Input Frame D Drives
Table 69 - Recommended AC Input Line Fuses - 460V AC Input Frame C Drives
Leg fuses and switches are located on the bus bars behind the control panel, which holds the circuit boards.
Fram
e
Drive
Current
Rating
Code
DC
Amps
AC Line
Amps
Qty Bussmann
Ferraz Shawmut (Gould Shawmut)
SIBA
Square Body - Flush End Contact
C 521
521
426
3
170M5466 + switch 170H0069
6,9 URD 32 TTF 1000 + switch MS 3-V1-5 BS
20 671 32.1000 + switch 28 001 04
700
700
571
3
170M5466 + switch 170H0069
6,9 URD 32 TTF 1000 + switch MS 3V 1-5 BS
20 671 32.1000 + switch 28 001 04
Fram
e
Drive
Current
Rating
Code
DC
Amps
AC Line
Amps
Qty
Bussmann
Ferraz Shawmut (Gould Shawmut)
SIBA
Square Body - DIN 43653 Stud-Mount
D
875
875
715
6
170M6263 + switch 170H0069
Y300263 + switch MS 3V 1-5 UR
20 635 32.900 + switch 28 001 04
1K0
1050
858
6
170M6264 + switch 170H0069
Z300264 + switch MS 3V 1-5 UR
20 635 32.1000 + switch 28 001 04
Fr
am
e
Drive
Current
Rating
Code
DC
Amps
AC Line
Amps
Qty Bussmann
Ferraz Shawmut (Gould Shawmut)
SIBA
Square Body - Flush End Contact
C 495
495
404.4
3
170M5464 + switch 170H0069
6,9 URD 32 TTF 800 + switch MS 3-V1-5 BS
20 671 32.800 + switch 28 001 04
667
667
544.9
3
170M5466 + switch 170H0069
6,9 URD 32 TTF 1000 + switch MS 3-V1-5 BS
20 671 32.1000 + switch 28 001 04