Table 15 - DIP Switch S14 Field Current Configuration Settings Frames A, B and C Drives
Table 16 - DIP Switch S14 Field Current Configuration Settings for Frame D Drives and Standalone
Regulators with a Rated Field Supply of 40 A
Table 17 - DIP Switch S14 Field Current Configuration Settings for Frame D Drives and Standalone
Regulators with a Rated Field Supply of 70 A
Switch ohms >
168.5
333.3
182
36.4
845
1668
3333
–
Equivalent
Resistance
Field Current Scale
S14-1
S14-2
S14-3
S14-4
S14-5
S14-6
S14-7
S14-8
Ohms
1 A
OFF
OFF
OFF
OFF
OFF
ON
Not used
(OFF)
1668
2 A
OFF
OFF
OFF
OFF
ON
OFF
845
3 A
OFF
OFF
OFF
OFF
ON
ON
560.9
5 A
OFF
ON
OFF
OFF
OFF
OFF
333.3
10 A
ON
OFF
OFF
OFF
OFF
OFF
168.5
13 A
ON
OFF
OFF
OFF
ON
ON
129.6
17 A
OFF
ON
ON
OFF
ON
ON
97.3
20 A
ON
OFF
ON
OFF
OFF
ON
83.1
Switch ohms >
168.5
333.3
182
36.4
845
1668
3333
–
Equivalent
Resistance
Field Current Scale
S14-1
S14-2
S14-3
S14-4
S14-5
S14-6
S14-7
S14-8
Ohm
1 A
OFF
OFF
OFF
OFF
OFF
OFF
ON
Not
used
(OFF)
3333
2 A
OFF
OFF
OFF
OFF
OFF
ON
OFF
1668
4 A
OFF
OFF
OFF
OFF
ON
OFF
OFF
845
6 A
OFF
OFF
OFF
OFF
ON
ON
OFF
560.9
10 A
OFF
ON
OFF
OFF
OFF
OFF
OFF
333.3
20 A
ON
OFF
OFF
OFF
OFF
OFF
OFF
168.5
30 A
ON
ON
OFF
OFF
OFF
OFF
OFF
111.9
40 A
ON
OFF
ON
OFF
OFF
ON
OFF
83.1
Switch ohms >
168.5
333.3
182
36.4
845
1668
3333
–
Equivalent
Resistance
Field Current Scale
S14-1
S14-2
S14-3
S14-4
S14-5
S14-6
S14-7
S14-8
Ohm
1 A
OFF
OFF
OFF
OFF
OFF
ON
OFF
Not
used
(OFF)
1668
5 A
OFF
ON
OFF
OFF
OFF
OFF
OFF
333.3
10 A
ON
OFF
OFF
OFF
OFF
OFF
OFF
168.5
20 A
ON
OFF
ON
OFF
OFF
ON
OFF
83.1
50 A
OFF
ON
OFF
ON
OFF
OFF
OFF
32.8
70 A
ON
ON
ON
ON
OFF
OFF
OFF
23.9