Rockwell Automation 20P PowerFlex Digital DC Drive User Manual
Page 186
186
Rockwell Automation Publication 20P-UM001I-EN-P - February 2013
Chapter 3
Programming and Parameters
INPUT
/
OUTPUT
D
igi
tal
O
u
tpu
ts
145
146
147
148
149
150
151
152
[Digital Out1 Sel]
[Digital Out2 Sel]
[Digital Out3 Sel]
[Digital Out4 Sel]
[Digital Out5 Sel]*
[Digital Out6 Sel]*
[Digital Out7 Sel]*
[Digital Out8 Sel]*
Selects the source of the value that drives the digital output. See “Option
Definitions” on Option Definitions for [Digital Outx Sel], [Relay Out 1 Sel]
and [Relay Out 2 Sel] on page
*These parameters are used to configure the digital outputs on the I/O
Expansion circuit board.
Note: Option 16 “Encoder Err” was changed for firmware version v5.002.
Options:
Default:
Default:
Default:
Default:
Default:
Default:
Default:
Default:
5 =
9 =
2 =
4 =
26 =
0 =
0 =
0 =
“Ready”
“Fault”
“Spd Thresh”
“CurrentLimit”
“Alarm”
“Not Used”
“Not Used”
“Not Used”
16-bit
Int
Fil
e
Gr
oup
No
.
Parameter Name & Description
See
page 110
for symbol descriptions
Values
Da
ta
T
yp
e
Rela
ted
0 =
“Not Used” (Off)
8 =
“Spd Limited”
16 = “Spd Fdbk Err”
24 = “Reserved”
1 =
“Spd Zero Thr”
9 =
“Fault”
17 = “Diam Calc”
25 = “Reserved”
2 =
“Spd Thresh”
10 = “Power Loss”
18 = “Input1 Cmp”
26 = “Alarm”
3 =
“At Speed”
11 =
“UserDefinedA”
19 = “Diam Reached”
27 = “Running”
4 =
“CurrentLimit”
12 =
“UserDefinedB”
20 = “Speed Match”
28 = “Jogging”
5 =
“Ready”
13 = “Stop Control”
21 = “Accelerating”
29 = “Active”
6 =
“Ramp Pos”
14 =
“Field Loss”
22 = “Decelerating”
7 =
“Ramp Neg”
15 =
“Spd Fbk Loss”
23 = “Brake Cmd”