Rockwell Automation 20P PowerFlex Digital DC Drive User Manual
Page 155
Rockwell Automation Publication 20P-UM001I-EN-P - February 2013
155
Programming and Parameters
Chapter 3
APPL
IC
AT
IONS
D
iamet
er Calc
798
[Dancer Constant]
The measurement corresponding to the total bunching of the material in the
dancer.
Default:
Min/Max:
Units:
1
1 / 10000
mm
16-bit
Int
799
[Minimum Diameter]
Minimum value of the roll diameter.
Default:
Min/Max:
Units:
100
1 / 2000
mm
16-bit
Int
800
[Diameter Calc St]
Status of the initial diameter calculation.
• “0” = The initial diameter calculation has not completed.
• “1” = The initial diameter calculation has completed.
Note: This parameter can be assigned to a digital output.
Default:
Min/Max:
Read Only
0 / 1
16-bit
Int
799
[Minimum Diameter]
Minimum value of the roll diameter.
Default:
Min/Max:
Units:
100
1 / 2000
mm
16-bit
Int
1153 [Max Diameter]
Maximum roll diameter.
Default:
Min/Max:
Units:
1.00
0.00 / 32.00
m
Real
1154 [Roll Diameter]
Displays the calculated roll diameter. Note: This parameter can be assigned to an
analog output as a percentage of Par 1153 [Max Diameter].
Default:
Min/Max:
Units:
Read Only
0.00 / 32.00
m
Real
1155 [Line Spd Thresh]
Line speed detecting threshold. When the value of Par 1286 [Ref Line Speed] is
lower than the value of [Line Spd Thresh], the diameter calculation stops and the
diameter is kept at a constant value. When the value of [Ref Line Speed] overcomes
the threshold, the diameter calculation is enabled with an initial filter
corresponding to the value in Par 1206 [Diam Init Filter] for the time set in Par 1207
[Diam Stdy Delay]. At the end of this time the filter will be set to the value of Par
1162 [Diameter Filter].
Default:
Min/Max:
Units:
5.00
0.00 / 150.00
%
Real
1162,
1206,
1207,
1286
1156 [Line Spd Gain]
Calibration value used to obtain Par 1160 [Line Speed Pct] = 100% at its maximum
value. The value of this parameter depends on the value of Par 1284 [Ref Spd
Source]:
[Line Spd Gain] = [32768 x 16384 / (maximum value of [Ref Spd Source] x 8)] -1
Default:
Min/Max:
0
0 / 32767
16-bit
Int
1160,
1284
1157 [Diameter Reset]
Diameter reset. When this parameter is set to “1”, the diameter starting value is set
to the value in Par 1168 [Diam Preset Sel].
Default:
Min/Max:
0
0 / 1
16-bit
Int
1168
1158 [Diam Threshold]
Diameter threshold as a percentage of Par 1153 [Max Diameter]. Par 1159
[Diameter Reached] is set to “1” when the value in this parameter is exceeded.
Default:
Min/Max:
Units:
10.00
0.00 / 150.00
%
Real
1153,
1159
1159 [Diameter Reached]
Indication that the diameter threshold set in Par 1158 [Diam Threshold] has been
exceeded.
• “0” = The diameter threshold has not been exceeded.
• “1” = The diameter threshold has been exceeded.
Default:
Min/Max:
Read Only
0 / 1
16-bit
Int
1158
1160 [Line Speed Pct]
Line speed.
Default:
Min/Max:
Units:
Read Only
0.00 / 150.00
%
Real
1161 [Diam Calc Dis]
Enables/Disables the diameter calculation (see also Par 1155 [Line Spd Thresh]).
The last calculated diameter value is saved if this parameter is changed to 0 “Off”
while the diameter is being calculated.
Default:
Options:
1 =
0 =
1 =
“On”
“Off”
“On”
16-bit
Int
1155
Fil
e
Gr
oup
No
.
Parameter Name & Description
See
page 110
for symbol descriptions
Values
Da
ta
T
yp
e
Rela
ted
A
A
A
A
A
A
A
A
A
A
A
A
A